Start the OCM application (P986110|ZJDE0001) and select the System data source. Add public records for all Version Workbench tables for all (non-J) environments in your system and make them active. The data source for these tables must be a central one, preferably ‘System’. Check that the ‘Allow QBE’ field is set to 1. The Version Workbench tables to create OCM records for are:
| Nr. | Table | Description |
|---|---|---|
| 01 | FQ46VW01 | Taskview Versions Workfile |
| 02 | FQ46VW02 | Task ID Sequence Numbering |
| 03 | FQ46VW03 | Task Master Orphanage |
| 04 | FQ46VW04 | Version Copy Configuration Header |
| 05 | FQ46VW05 | Version Copy Configuration Detail |
| 06 | FQ46VW06 | Freezepoint Master |
| 07 | FQ46VW07 | Freezepoint Detail |
| 08 | FQ46VW08 | Processing Option Freezepoint |
| 09 | FQ46VW09 | Compare Processing Option Freezepoints |
| 10 | FQ46VW10 | Data Selection Freezepoint |
| 11 | FQ46VW11 | Data Sequence Freezepoint |
| 12 | FQ46VW12 | Compare Data Selection Freezepoints |
| 13 | FQ46VW13 | Compare Data Sequence Freezepoints |
| 14 | FQ46VW14 | Freezepoint Generation in Process |
| 15 | FQ46VW15 | Freezepoint Generation Scope – Versions |
| 16 | FQ46VW16 | Freezepoint Generation Scope – Objects |
| 17 | FQ46VW17 | Freezepoint Generation Scope |
| 18 | FQ46VW18 | Project Versions Workfile |
| 19 | FQ46VW19 | Task Relationship Orphanage |
| 20 | FQ46VW20 | Taskview Generation Loopback Workfile |
| 21 | FQ46VW22 | Task Master Workfile |
| 22 | FQ46VW23 | Task Relationships Workfile |
| 23 | FQ46VW24 | Task Alternate Descriptions Workfile |
| 24 | FQ46VW90 | Version Workbench Logging |
| 25 | FQ46VW91 | Version Workbench Next Numbering |
| 26 | FQ46VW92 | Version Workbench Logging Detail |
| 27 | FQ46VW93 | Development Configuration |
| 28 | FQ46VW99 | Version Workbench Validation (obsolete in the 64Bit version of VW |
For a regular system installation with DV, PY and PD this should result in 84 (28 * 3) OCM entries for Version Workbench tables. You can check by querying for FQ46VW* in the Object Name QBE column.
Start the OCM application (P986110|ZJDE0001) and select the System data source. Add public records for all Version Workbench batch applications for all (non-J) environments in your system and make them active. The data source for these batch applications must be be specified as LOCAL. The Version Workbench batch applications to create OCM records for are:
| Nr. | Table | Description |
|---|---|---|
| 01 | RQ46VW50 | Generate Freezepoint |
| 02 | RQ46VW51 | Restore PO Freezepoint |
| 03 | RQ46VW52 | Freezepoint Copy |
| 04 | RQ46VW53 | Processing Option Freezepoint |
| 05 | RQ46VW54 | Export Freezepoint |
| 06 | RQ46VW55 | Import Freezepoint |
| 07 | RQ46VW56 | Compare PO Freezepoints |
| 08 | RQ46VW57 | Data Selection Freezepoint |
| 09 | RQ46VW58 | Data Sequence Freezepoint |
| 10 | RQ46VW59 | Generate Compare Freezepoints |
| 11 | RQ46VW60 | Compare DS Freezepoints |
| 12 | RQ46VW61 | Compare DQ Freezepoints |
For a regular system installation with DV, PY and PD this should result in 36 (12 * 3) OCM entries for Version Workbench batch applications. You can check by querying for RQ46VW* in the Object Name QBE column.